Automatic closing
1
4
7
2
5
83 6
ON
DIP
Automatic closing deactivated.
1
4
7
2
5
83 6
ON
DIP
Automatic closing without light barrier reduction
The door closes after a delay of 1 minute. If the door encounters an ob‐
struction, automatic closing is aborted after 5 unsuccessful attempts.
The door must then be moved to the lower limit position using the but‐
tons on the control unit or a hard-wired device.
1
4
7
2
5
83 6
ON
DIP
Automatic closing with light barrier reduction to 3 seconds
The door is closed after a delay of 1 minute. This time is reduced to 3
seconds by passing the light barrier. If the door encounters an obstruc‐
tion, automatic closing is aborted after 5 unsuccessful attempts. The
door must then be moved to the lower limit position using the buttons
on the control unit or a hard-wired device.
1
4
7
2
5
83 6
ON
DIP
Automatic closing with light barrier reduction to 15 seconds
The door is closed after a delay of 1 minute. This time can be reduced
to 15 seconds by passing the light barrier. If the door encounters an
obstruction, automatic closing is aborted after 5 unsuccessful at‐
tempts. The door must then be moved to the lower limit position using
the buttons on the control unit or a hard-wired device.