13
Miditherm MP
Checking a program
• Switch on unit. The current temperature of the
furnace is displayed after approx. 3 seconds.
‚ Select program:
• Press as often until LED lights up.
• Press / until desired
program number appears.
ƒ Check values:
Press / to check the values of
• heating-up speed (°C/min),
• holding temperature (°C) and
• holding time (min.).
„ To check the next holding level, go to the field
using the / buttons and call up the next
holding level using the / buttons.
Check the settings at this holding level as
described in point ƒ.
… The current furnace temperature is displayed
again approx. 10 seconds after the last button was
pressed. The check is now finished.
‚
•
3 x
22
22
2
Notes
• The current furnace temperature is displayed
again approx. 10 seconds after the last button
was pressed. This also happens when hesitating
too long before pressing the next key.
• Always check all holding levels! All values in the
unused holding levels of a program must be set
to “0”.
• Changing values: see “Creating a new program”.