Miditherm MP
Starting a program
3 x
22
22
2
Switch on unit. The current temperature of the
furnace is displayed after approx. 3 seconds.
Select program:
Press as often until LED lights up.
Press / until desired
program number appears.
ƒ Start program:
Press .
LED lights up.
LED „°C“ lights up, display shows
increasing furnace temperature.
LED lights up, display shows
time of end of program.
When a holding temperature is reached, the
LED “min” lights up and the remaining minutes
of the holding time are displayed..
At the end of the program an acoustic signal
sounds and LED flashes.
End program (furnace cools down):
press .
Hold furnace temperature:
do not press .
ƒ
Notes
Only with shock heat investment materials:
Risk of injury during shock heating!
Place all moulds in the furnace within
10 seconds - then keep the furnace door
closed for 15 minutes!
After program start it takes around 5 minutes
for the furnace temperature to rise.
Information on next holding temperature:
press (only during heating-up process).
Turn off acoustic signal after end of program:
open and close furnace door.
To turn off permanently: see page 18.
After short power failures the program remains
stored and is resumed. Thus, the program
cannot be ended by means of the master switch.