14
Miditherm MP
Starting a program
‚
•
3 x
22
22
2
• Switch on unit. The current temperature of the
furnace is displayed after approx. 3 seconds.
‚ Select program:
• Press as often until LED lights up.
• Press / until desired
program number appears.
ƒ Start program:
Press .
• LED lights up.
• LED „°C“ lights up, display shows
increasing furnace temperature.
• LED lights up, display shows
time of end of program.
When a holding temperature is reached, the
LED “min” lights up and the remaining minutes
of the holding time are displayed..
„ At the end of the program an acoustic signal
sounds and LED flashes.
• End program (furnace cools down):
press .
• Hold furnace temperature:
do not press .
ƒ
Notes
Only with shock heat investment materials:
Risk of injury during shock heating!
Place all moulds in the furnace within
10 seconds - then keep the furnace door
closed for 15 minutes!
• After program start it takes around 5 minutes
for the furnace temperature to rise.
• Information on next holding temperature:
press (only during heating-up process).
• Turn off acoustic signal after end of program:
open and close furnace door.
To turn off permanently: see page 18.
• After short power failures the program remains
stored and is resumed. Thus, the program
cannot be ended by means of the master switch.