Miditherm MP
Reducing or increasing temperature in running program
Example
After the end of the program (LED flashes)
the furnace temperature is 800°C. Further heating
to 900°C is desired.
Keep depressed until LED “°C/min.” flashes.
Press (LED „°C“ flashes).
ƒ Press / until desired temperature
appears.
Keep depressed until LED “°C” lights up.
Notes
To change the temperature during the running
program, never press the button!
Pressing this button ends the program. Pressing
it again would restart the program, beginning
with holding level 1.
The temperature of the furnace can be changed
at every time of a running program. The change
will not be stored permanently in the program.
. . . .