17
Miditherm MP
Settings
P1 = weekday setting
P2 = time setting (hours)
P3 = time setting (minutes)
•
…
The time must be set after installation and when
changing between summer and winter daylight sav-
ing time.
• When switching on, keep button depressed:
display shows “P1” (after approx. 3 seconds)
and acoustic signal sounds.
‚ Set weekday with / buttons:
1 = Monday, 2 = Tuesday, .... , 7 = Sunday.
ƒ Press button to call up “P2” and set time
(hours) with / buttons
„ Press button to call up “P3” and set time
(minutes) with / buttons.
… Press button 4 times:
Display shows the current furnace temperature
(after approx. 7 seconds).
“Day and time” setting is finished.
Notes
• For setting P4 (acoustic signal) and P5 (cutout
temperature of the suction extraction unit) see
page 18.
• P6 has no function.