18
Miditherm MP
Settings
•
†
At the end of a program an acoustic signal sounds.
If desired, the signal can be switched off permanently.
The Regulus extraction system can be connected to
the rear socket. You can set up to what furnace tem-
perature the suction extraction unit is supplied with
power.
• When switching on unit, keep depressed:
display shows “P1” (after approx. 3 seconds)
and acoustic signal sounds.
‚ Press 3 times: display shows „P4“.
ƒ Press / : 1 = signal on
0 = signal off
„ Press : display shows „P5“.
… Press / to set the cut-out temperature
of the Regulus extraction system. The factory
setting (600°C) is adequate for customary
investment materials that are heated up slowly.
For shock heat investment materials, the Regulus
furnace extraction system must be set to
continuous operation (see page 12).
† Press twice:
display shows the current furnace temperature
(after approx. 7 seconds).
Notes
• Setting from P1 to P3 (weekday, time):
see „Setting day and time“.
• P6 has no function.
P 4
P 5
Acoustic signal /
cut-out temperature of
extraction system