Installation EAGLE40
Release
02
08/2020
43
EMC and immunity
Note: You will find detailed information on the certificates and
declarations applying to your device in a separate overview.
See table 5 on page 16.
EMC interference emission Standard
applications
Radiated emission
EN 55032 Class A
FCC 47 CFR Part 15 Class A
EN 61000-6-4 Fulfilled
EMC interference immunity Standard
applications
Electrostatic discharge
EN 61000-4-2 Contact discharge ± 4 kV
EN 61000-4-2 Air discharge ± 8 kV
Electromagnetic field
EN 61000-4-3 80 MHz ... 1000 MHz 10 V/m
1.4GHz ... 6.0GHz 3V/m
Fast transients (burst) - power supply connection
EN 61000-4-4 ±2 kV
Fast transients (burst) - data line
EN 61000-4-4 ± 1 kV
Voltage surges - power supply connection
EN 61000-4-5 line/ground ± 1 kV
EN 61000-4-5 line/line ± 0.5 kV
Voltage surges - data line
EN 61000-4-5 line/ground ± 1 kV
Conducted disturbances
EN 61000-4-6 150 kHz ... 80 MHz 10 V