XPR-9 Series Two-Post Lifts
38
P/N 5900371 — Rev. D2 — May 2023
2. If you are adding Thread Sealant to a Fitting or connector that has already
been used with a different sealant, use a wire brush to thoroughly remove the
old sealant before adding more.
3. Skipping the top thread, apply a small amount of Thread Sealant to the next
four threads of the Fitting.
⚠ WARNING Always wear the proper protective equipment when handling
Thread Sealant.
You only need a small amount because the sealant spreads to the other
threads as it is tightened into place.
If you put too much, the excess liquid will be pushed out when the Fitting is
tightened; use a rag to wipe the excess.
4. Tighten the Fitting into the connector; do not over tighten the Fitting.
5. Allow the manufacturer-recommended curing time before pressurizing the system.
Routing the Hydraulic Hoses – XPR-9TF
The following illustration shows how to connect the XPR-9TF Hydraulic Hoses to the Hydraulic
Cylinders.