500V
250V 1000V
PV 2
DIN EN 62446 (VDE 0126-23), DIN EN 61829 (VDE 0126-24)
Auto Mode
a Vo/c, Is/c, MΩ
b Vmpp, Impp, FF
c a + b
d
Auto
Ω
NULL
R
PE
Mode
R
ISO
V
ISO
5
%
NULL
BENNING PV 2
D
Bedienungsanleitung
Operating manual

Table of Contents

Other manuals for Benning PV 2

Question and Answer IconNeed help?

Do you have a question about the Benning PV 2 and is the answer not in the manual?

Benning PV 2 Specifications

General IconGeneral
DisplayLCD
Power MeasurementYes
Voltage Measurement Range0-1000V DC
Insulation Resistance MeasurementNo
Safety RatingCAT III 1000V
DC Voltage Measurement Accuracy±1%
DC Current Measurement Range0-10A DC
DC Current Measurement Accuracy±1%
Continuity TestNo
Diode TestNo
Safety StandardIEC 61010
Accuracy±1%

Summary

Device Unit Description

Appliance Front Face Overview

Visual guide to the BENNING PV 2 device's front panel, including controls and display.

Top Side Device Features

Description of the BENNING PV 2's top side, highlighting connectors and ports.

Digital Display Indicators

Explanation of symbols, readings, and status messages on the BENNING PV 2 display.

Electrical Specifications

Protective Conductor Resistance Specs

Technical details for RPE measurement, including current and accuracy.

Open-Circuit Voltage Specs

Specifications for measuring PV module/string open-circuit voltage (Vo/c).

Short-Circuit Current Specs

Specifications for measuring PV module/string short-circuit current (Is/c).

Insulation Resistance Specs

Technical details for Riso measurement, including test voltages and accuracy.

Voltage Measurement Specifications

Specs for voltage measurements using the device's 4mm test sockets.

Current Clamp Measurement Specs

Specs for current measurements using the optional BENNING CC 3 adapter.

Measurement Procedures

Measurement Preparation Steps

Essential steps before taking measurements, including device settings.

Testing Protective Conductor Resistance

Step-by-step guide for performing RPE tests on PV systems.

Automatic PV Generator Measurements

Procedure for automated measurements on PV generators.

AC/DC Voltage Measurement Guide

Instructions for performing AC and DC voltage measurements.

Insulation Resistance Measurement Guide

Steps for conducting insulation resistance tests (2-pin method).

Measured Value Memory Operations

How to store, recall, and manage measured data in the device memory.

Radio Connection to BENNING SUN 2

Guide to establishing radio communication with the BENNING SUN 2.

Maintenance and Safety Procedures

Error Codes and Troubleshooting

Comprehensive list of error codes and their corresponding remedies.

Battery and Fuse Replacement

Detailed instructions for replacing the device's batteries and fuses.

Calibration and Environmental Disposal

Information on instrument calibration and proper end-of-life disposal.