16
caldaie
3 SWITCHING OFF BOILER
3.1 TEMPORARY SWITCHING OFF
Turn the function selector (Fig. 3.1) to OFF for temporary
absence (weekend, short journeys, etc.).
While the electricity and fuel supply is still working, the boiler
is protected by systems:
- Circulator anti-blockage: the circulator starts every 24
hours of stand-by and after 3 hours from the last time the
sanitary system was used.
- Antifreeze: this will be started if the temperature of the
water in CH circuit falls to below 7°C, the circulator is timed
for a cycle of 15 min. every 2 hours and the circulator will
switch itself off when the temperature of the water in the
boiler exceeds 10°C. The burner will ignite at the lowest
heating when the temperature of the water primary drops to
below 5°C until the temperature of the water reaches 30°C.
3.2 SWITCHING OFF FOR LONG PERIODS
IThe following operations should be done for CIAO boilers that
are not going to be used for long periods:
- Turn the function selector (Fig. 3.1) to OFF;
- turn the system’s main switch to “OFF” and check that the
green LED has gone off;
- turn off the fuel and water taps of the heating and sanitary
system.
!!
Fig. 3.1
Fig. 3.2
In this case the antifreeze and antiblockage systems are
disconnected.
Empty the heating and sanitary systems if there is any
danger of freezing.
!!