59
caldaie
CIAO C.A.I. - C.S.I.
Starting up inspection
LED YELLOW
LED GREEN
LED RED
STARTING UP INSPECTION
NO
NO
YES
NO
CHECK FOR
GAS UPSTREAM FRO
M GAS VALVE
See section 2.4
page 13
ADJUST GAS PRESSURE
AND EVENTUALLY CHECK FIL
TER AT VALVE INLET
(See section 2.4 page 13)
CHECK FUMES THERMOSTAT (C.A.I)
AND/OR LIMIT THERMOSTAT
page 62 C.A.I., page 63 C.S.I.
THERE
ARE 230 VAC
BETWEEN GAS VALVE
TERMINALS
See appendix - E
pages 81-82
REPLACE GAS VALVE COILS
See table 4.4.16 pages 40, 41
CHECK WIRING AND CONNECTIONS
See appendix- E pages 81-82
THERE ARE
230 VAC BETWEEN
TERMINALS M1.27 AND
M1.29 ON THE ELECTRONIC
CONTROL BOARD
See appendix - E
pages 81-82
YES