60
caldaie
NO
NO
YES
NO
NO
CIRCULATOR
INSPECTION
CIRCULATOR
IS BLOCKED
see section 2.1 page 11
FREE THE CIRCULATOR
THROUGH THE SHAFT
see section 2.1 page 11
THERE ARE
230 VAC BETWEEN
TERMINALS M5.20 AND
M5.21 ON THE ELECTRON
IC CONTROL BOARD
see APPENDIX - E
pages 81-82
REPLACE THE ELECTRONIC
CONTROL BOARD
see table 4.4.9 page 32
THERE ARE
230 VAC BETWEEN
CIRCULATOR TERMINALS
see APPENDIX - E
pages 81-82
CHECK WIRING AND
CONNECTIONS
see APPENDIX - E pages 81-82
REPLACE THE CIRCULATOR
see table 4.4.2 page 20
YES