64
caldaie
CIAO C.S.I.
Fan testing
NO
NO
NO
YES
FAN TESTING
THERE
ARE 230 VAC BETWEEN
TERMINALS M6.22 AND M6.23
ON THE ELECTRONIC
CONTROL BOARD
see APPENDIX - E
pages 81-82
THERE
ARE 230 VAC BETWEEN
FAN TERMINALS
see section 1.5.20
page 7
REPLACE FAN
see table 4.4.19 page 44
CHECK WIRING AND
CONNECTIONS
see APPENDIX - E pages 81-82
THERE ARE
0 VDC BETWEEN
TERMINALS M6.24 AND M6.25
ON THE ELECTRONIC
CONTROL BOARD
see APPENDIX - E
pages 81-82
REPLACE THE ELECTRONIC
CONTROL BOARD
see table 4.4.9 page 32
CONTINUITY
ON FUMES PRESSURE
SWITCH TERMINALS
see section 1.5.8
page 4
REPLACE FUMES
PRESSURE SWITCH
see table 4.4.7 page 27
CHECK WIRING AND
CONNECTIONS
see APPENDIX - E pages 81-82
YES
YES
YES
YES
LED YELLOW
LED GREEN
LED RED