65
caldaie
CIAO C.A.I.
Working tests for boiler on heating
6. WORKING TESTS
• Working tests for boiler on heating (C.A.I.) page 65
• Working tests for boiler on heating (C.S.I.) page 66
• Working tests for boiler on sanitary page 67
!!
Unless indicated otherwise, the values are valid for both
the C.A.I. and the C.S.I. versions.
LED YELLOW
LED GREEN
LED RED
DO TEST B Page 69 C.A.I.
CIRCULATOR ON
START
CLOSE TERMINALS M3.4 AND M3.6 ON THE
ELECTRONIC CONTROL BOARD
See appendix - E pages 81-82
GREEN ON LED
FLASHING
DO TEST A page 68
NO
CIRCULATOR
INSPECTION Page 60
TURN THE ON/OFF SELECTOR TO
HEATING POSITION WITH HEATING
TEMPERATURE AT MAXIMUM
See section 2.2 page 11
NO
YES
YES