SETUP CTR - VIBRATO – SENSE LVR
This setting controls vibrato lever sensitivity. As individual vibrato sensors may
vary in values a bit, this setting will help adjusting the sensitivity to get the best
result. Setting values go from 1 to 12, where 12 is the most sensitive.
SETUP CTR - VIBRATO – SQUELCH L
This setting helps eliminate pitch bend MIDI chatter for when vibrato is not
touched and idle. Setting it too high makes the vibrato lever require an
unnecessary amount of movement before initiating vibrato, and with the setting
too low the natural sensor noise will cause MIDI chatter around zero. To find the
right setting, use a MIDI monitor software on your computer or other device. It
should not be showing pitch bend activity when idle, yet be set close enough to
this limit to allow good sensitivity when lever is touched slightly. When you are
pleased with the setting, press ENTER or MENU to save it. Setting values go
from 1 to 30, where 12 is the factory default.
SETUP CTR - VIBRATO – SENSE BTE
This setting controls vibrato sensitivity. As individual vibrato sensors may
vary in values a bit, this setting will help adjusting the sensitivity to get the best
result. Setting values go from 1 to 12, where 12 is the most sensitive.
SETUP CTR - VIBRATO – SQUELCH B
This setting helps eliminate pitch bend MIDI chatter for when bite vibrato is
not touched and idle. Setting it too high makes the bite sensor require an