EasyManua.ls Logo

Berthoud WIN'AIR 600 - Sprayer Noise Levels; Sprayer Dimensions and Measurements

Default Icon
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
1.4. SOUND MEASUREMENTS
Atmospheric noise emitted by: WIN'AIR trailed sprayer equipped with arch.
- Sound pressure Driver's environment LPA in dB(A):
- Tractor alone = 69.4
- Tractor + sprayer = 72.5
- Sound pressure Peak level:
- Tractor alone = 92.8
- Tractor + sprayer = 96.1
- Sound power LWA:
- Tractor alone = 104.35
- Tractor + sprayer = 116.18
Comply with the legislation in force and use ear-protectors if necessary.
1.5. DIMENSIONS
LA
C
B
H
WIN'AIR
600
WIN'AIR
800
WIN'AIR
1000
WIN'AIR
1500
H = HEIGHT UNDER BOOM in mm
(according to the type of lift and mounting of tyres)
B
438 442 465 402 Manual lift
Hydraulic lift
340 mm
Hydraulic lift
500 mm
Type of wheel
L in mm (Min. / Max.)
Min. Max. Min. Max. Min. Max.
165 R13 990 / 1230 1836 2436 1858 2198 2006 2506
185 R14 1060 / 1290 1850 2450 1872 2212 2020 2520
215/75 R15 1100 / 1320 1947 2547 1969 2309 2117 2617
235/80 R15 1290 / 1665 1943 2543 1943 2283 2113 2613
10.0/75 x 15.3 1190 / 1370 1300 / 1630 1965 2565 1987 2327 2135 2635
31/15.5 - 15 1470 / 1800 1544 / 1760 2000 2600 2022 2362 2170 2670
A
2680 2990 3160 3470
Tank width
C
950 1020 1020 1020

Related product manuals