What does message “End” mean on my Binder C 170?
- SStephanie HernandezSep 8, 2025
If your Binder Laboratory Equipment displays the message “End”, it means the sterilization cycle has completed. Start up the unit.
What does message “End” mean on my Binder C 170?
If your Binder Laboratory Equipment displays the message “End”, it means the sterilization cycle has completed. Start up the unit.
What to do if my Binder C 170 Laboratory Equipment shows message “dor”?
If your Binder Laboratory Equipment displays the message “dor”, it indicates that the outer unit door is not closed properly. Ensure that you close the unit door properly.
How to fix a Binder C 170 Laboratory Equipment with no unit function and a dark display?
If your Binder Laboratory Equipment shows no unit function and a dark display, the main power switch is likely off. Turn on the main power switch to resolve this.
How to troubleshoot a Binder Laboratory Equipment with no function?
If your Binder Laboratory Equipment is not functioning, start by checking the connection to the power supply. Also, verify that the power supply voltage matches the unit's requirement of 120 V / 230 V.
Why is the CO concentration inside my Binder Laboratory Equipment too low?
If the CO concentration inside your Binder Laboratory Equipment is too low, it could be due to several reasons: * Doors not closed properly: Ensure the door is tightly shut. * Defective door gaskets: Consider replacing the door gaskets. * CO cylinder issues: Make sure the CO cylinder is correctly connected, and that the cylinder is open and not empty. * Gas hose: Check the gas hose for any dirt accumulation or obstructions; clean or replace if necessary. If these steps don't resolve the issue, it may require professional attention.
What to do if sterilization program started with the CO sensor still plugged-in in Binder C 170?
To solve this problem, pull the CO sensor and remove it from the incubator.
What does alarm message “ - - - ” on my Binder C 170 Laboratory Equipment mean?
If your Binder Laboratory Equipment displays an alarm message “ - - - ”, connect the CO sensor.
How to resolve alarm message “Loc” on my Binder C 170?
To resolve the “Loc” alarm message on your Binder Laboratory Equipment, enter the password for unlocking and then start the sterilization again.
Why is there condensation on the door of my Binder C 170?
If you see condensation on the door of your Binder Laboratory Equipment, it could be due to several reasons: * The unit is placed on a very cold floor. Place the unit on a BINDER stand to increase the distance to the floor. * The doors are not closed properly. Make sure to close the door properly. * The door gaskets are defective. Replace the door gaskets.
What to do if CO concentration inside my Binder C 170 is too low and message “con” is displayed?
If the CO concentration inside your Binder Laboratory Equipment is too low and the message “con” is displayed, make sure that the doors are closed properly and replace the door gaskets if they are defective.
Information about the manual's purpose, liability disclaimers, and product changes.
Explains safety symbols, signal words, pictograms, and message panel structure.
Details the placement of warning signs and service labels on the CO2 incubator.
Describes the details and meaning of information presented on the unit's type plate.
Provides essential safety guidelines for installing and operating the CO2 incubator.
Health hazards of CO2, ventilation requirements, and recommended warning systems.
Safe practices for storing, transporting, securing, and using gas cylinders.
Defines the approved applications and usage guidelines for the C 170 incubator.
Explains the FPI sensor system and infrared measurement technology for CO2.
Identifies key external components of the incubator such as the controller and door handle.
Details the rear connection panel, including fuses, Ethernet, and alarm contacts.
Discusses the outer door heater, inner glass door, and automatic CO2 valve closure.
Instructions for unpacking, checking for damage, and removing protective materials.
Guidelines for safely lifting, moving, and transporting the unit.
Recommendations for intermediate storage, including temperature and humidity limits.
Requirements for the installation site, surface, ventilation, and ambient conditions.
Instructions for installing and assembling the shelf holders and shelves.
Details on connecting the CO2 sensor and general operational notes.
Instructions for properly placing and filling the water pan for humidity.
General information and precautions for connecting gas cylinders.
Instructions for connecting the unit to the power supply, including voltage and fuse details.
Lists the default settings for temperature, CO2, and safety controller.
Discusses the initial equilibration phase and precautions before placing samples.
Guides on navigating the controller display and setting parameters.
Details how to access and use the HAND operating mode for setting functions.
Instructions for accessing and using the password-protected USER mode.
Explains how to lock/unlock settings using a password in HAND mode.
Describes unit behavior during power interruptions and after restart.
How to enter installation altitude for CO2 concentration correction.
Step-by-step guide to setting desired temperature and CO2 levels.
Describes the function of internal class 1 safety devices for unit protection.
Explains the independent safety controller for protecting samples from overheating.
How to select between 'Limit' and 'Offset' types for the safety controller.
Procedure for setting the safety controller's temperature limit or offset value.
Lists various alarm displays, their meanings, and triggering events.
Steps to clear alarm messages and turn off audible alerts.
How the unit transmits alarms to external monitoring systems via relay contacts.
Details the alarm triggered when the safety controller set point is exceeded.
Explains alarms for deviations from set temperature outside tolerance limits.
Describes the alarm and control shutdown when the incubator door is left open.
Alarms for CO2 levels deviating from the set point or tolerance threshold.
Alarm indicating insufficient CO2 supply pressure.
Describes alarms and actions for temperature sensor malfunctions.
Identifies the alarm for a defective CO2 sensor and required steps.
Describes methods for verifying CO2 concentration using pH or indicator tubes.
Guidelines for performing accurate temperature reference measurements.
Describes optional silicone ports for cable entry and their usage.
Recommends the optional base for easier access and contamination avoidance.
Optional adapter for safe stacking of incubators.
Describes optional analog outputs for data transmission.
Precautions regarding cell cultures, media, sera, and reagents to prevent contamination.
Measures for maintaining a contamination-free lab environment and equipment.
Importance of aseptic techniques, safety training, and personnel behavior.
Features of the incubator's design that reduce contamination risk.
General handling advice to reduce contamination from installation, doors, and cleaning.
Procedures and recommended cleaning agents for exterior and interior surfaces.
Steps for chemical decontamination and recommended disinfectants.
Specific instructions for cleaning and disinfecting the CO2 sensor.
Details the automatic hot-air sterilization cycle, including its phases and duration.
Explains how and when the sterilization cycle can be aborted.
Information on service, maintenance, warranty, and contact details.
How to check the operation of the air jacket heating fan.
Explains the function of the gas fine filter and its replacement.
Instructions for disposing of transport packaging materials.
Steps for safely shutting down and preparing the unit for decommissioning.
Legal requirements for disposing of the unit in Germany according to WEEE directive.
Disposal regulations for EC member states outside Germany, following WEEE.
Guidelines for disposal in countries outside the EC, emphasizing local regulations.
Troubleshooting for general unit issues like no power or message displays.
Troubleshooting common heating problems like chamber not heating or temperature deviations.
Troubleshooting gas pressure, CO2 concentration, and supply problems.
Troubleshooting problems related to humidity, condensation, and door gaskets.
Troubleshooting controller errors, messages, and alarm indications.
Information on the unit's factory calibration process and standards.
Details the miniature fuse for over-current protection and its replacement.
Explains how the usable volume is calculated and provides usage guidelines.
Comprehensive technical specifications of the C 170 incubator.
Provides important conversion factors for units not using the SI system.
A table for converting gas inlet pressures between bar and psi.
Lists the standard equipment and available optional accessories for the C 170.
Provides a list of available accessories and spare parts with their article numbers.
Technical drawings and detailed dimensions of the C 170 incubator.
The EC Declaration of Conformity document confirming compliance with EU directives.
Form for declaring safety and health information for returning units outside North America.
Form for product return authorization and decontamination declaration for North America.
Information about the manual's purpose, liability disclaimers, and product changes.
Explains safety symbols, signal words, pictograms, and message panel structure.
Details the placement of warning signs and service labels on the CO2 incubator.
Describes the details and meaning of information presented on the unit's type plate.
Provides essential safety guidelines for installing and operating the CO2 incubator.
Health hazards of CO2, ventilation requirements, and recommended warning systems.
Safe practices for storing, transporting, securing, and using gas cylinders.
Defines the approved applications and usage guidelines for the C 170 incubator.
Explains the FPI sensor system and infrared measurement technology for CO2.
Identifies key external components of the incubator such as the controller and door handle.
Details the rear connection panel, including fuses, Ethernet, and alarm contacts.
Discusses the outer door heater, inner glass door, and automatic CO2 valve closure.
Instructions for unpacking, checking for damage, and removing protective materials.
Guidelines for safely lifting, moving, and transporting the unit.
Recommendations for intermediate storage, including temperature and humidity limits.
Requirements for the installation site, surface, ventilation, and ambient conditions.
Instructions for installing and assembling the shelf holders and shelves.
Details on connecting the CO2 sensor and general operational notes.
Instructions for properly placing and filling the water pan for humidity.
General information and precautions for connecting gas cylinders.
Instructions for connecting the unit to the power supply, including voltage and fuse details.
Lists the default settings for temperature, CO2, and safety controller.
Discusses the initial equilibration phase and precautions before placing samples.
Guides on navigating the controller display and setting parameters.
Details how to access and use the HAND operating mode for setting functions.
Instructions for accessing and using the password-protected USER mode.
Explains how to lock/unlock settings using a password in HAND mode.
Describes unit behavior during power interruptions and after restart.
How to enter installation altitude for CO2 concentration correction.
Step-by-step guide to setting desired temperature and CO2 levels.
Describes the function of internal class 1 safety devices for unit protection.
Explains the independent safety controller for protecting samples from overheating.
How to select between 'Limit' and 'Offset' types for the safety controller.
Procedure for setting the safety controller's temperature limit or offset value.
Lists various alarm displays, their meanings, and triggering events.
Steps to clear alarm messages and turn off audible alerts.
How the unit transmits alarms to external monitoring systems via relay contacts.
Details the alarm triggered when the safety controller set point is exceeded.
Explains alarms for deviations from set temperature outside tolerance limits.
Describes the alarm and control shutdown when the incubator door is left open.
Alarms for CO2 levels deviating from the set point or tolerance threshold.
Alarm indicating insufficient CO2 supply pressure.
Describes alarms and actions for temperature sensor malfunctions.
Identifies the alarm for a defective CO2 sensor and required steps.
Describes methods for verifying CO2 concentration using pH or indicator tubes.
Guidelines for performing accurate temperature reference measurements.
Describes optional silicone ports for cable entry and their usage.
Recommends the optional base for easier access and contamination avoidance.
Optional adapter for safe stacking of incubators.
Describes optional analog outputs for data transmission.
Precautions regarding cell cultures, media, sera, and reagents to prevent contamination.
Measures for maintaining a contamination-free lab environment and equipment.
Importance of aseptic techniques, safety training, and personnel behavior.
Features of the incubator's design that reduce contamination risk.
General handling advice to reduce contamination from installation, doors, and cleaning.
Procedures and recommended cleaning agents for exterior and interior surfaces.
Steps for chemical decontamination and recommended disinfectants.
Specific instructions for cleaning and disinfecting the CO2 sensor.
Details the automatic hot-air sterilization cycle, including its phases and duration.
Explains how and when the sterilization cycle can be aborted.
Information on service, maintenance, warranty, and contact details.
How to check the operation of the air jacket heating fan.
Explains the function of the gas fine filter and its replacement.
Instructions for disposing of transport packaging materials.
Steps for safely shutting down and preparing the unit for decommissioning.
Legal requirements for disposing of the unit in Germany according to WEEE directive.
Disposal regulations for EC member states outside Germany, following WEEE.
Guidelines for disposal in countries outside the EC, emphasizing local regulations.
Troubleshooting for general unit issues like no power or message displays.
Troubleshooting common heating problems like chamber not heating or temperature deviations.
Troubleshooting gas pressure, CO2 concentration, and supply problems.
Troubleshooting problems related to humidity, condensation, and door gaskets.
Troubleshooting controller errors, messages, and alarm indications.
Information on the unit's factory calibration process and standards.
Details the miniature fuse for over-current protection and its replacement.
Explains how the usable volume is calculated and provides usage guidelines.
Comprehensive technical specifications of the C 170 incubator.
Provides important conversion factors for units not using the SI system.
A table for converting gas inlet pressures between bar and psi.
Lists the standard equipment and available optional accessories for the C 170.
Provides a list of available accessories and spare parts with their article numbers.
Technical drawings and detailed dimensions of the C 170 incubator.
The EC Declaration of Conformity document confirming compliance with EU directives.
Form for declaring safety and health information for returning units outside North America.
Form for product return authorization and decontamination declaration for North America.
| Brand | Binder |
|---|---|
| Model | C 170 |
| Category | Laboratory Equipment |
| Language | English |
Loading...