For best results, use knife and plate as a set. Do not operate machine for any period of time
without product in the grinding bowl. This will cause heating and dulling of the knife and plate.
OPERATION
5
10. Two sets of green and red pushbuttons are located at the front of the machine that activate the magnetic
contacts that control the mix and grind motors. The time delay product mixer safety cover interlock
switch is mounted in the motor compartment. The product mixer safety cover cannot be opened
until the time delay interlock switch times out (which will be after the grinding auger comes to a
complete stop.)
12. If machine runs clockwise(backwards), it must be rewired to correct rotation, otherwise serious
irreparable damage may occur to the grinding components. The grinding auger must operate in the proper
direction.
13. Check operation of optional footswitch if equipped. Plug footswitch cord into tting at bottom of
contactor box. Turn toggle selector to foot. The machine will operate with pressure on the footswitch
treadle. Releasing the treadle stops the machine. The footswitch operates both the mix and grind together.
14. Insert grinding auger assembly into the bowl and fully engage the auger into the drive shaft. Place knife
rst (sharp edges out) then grinding plate into end of grinding bowl. The grinding plate slides over the
knife drive pin, and is held from rotating during operation by three pins in the grinding bowl. Install the
end retaining ring.
ONLY HAND TIGHTEN END RETAINING RING
15. Check placement of all warning labels and Manual. Machine is now ready for trained operators to process
product.
16. Use meat deector attached to grinding bowl to eliminate meat splatter.
17. Contact your local Distributor or BIRO directly if you have any questions or problems with the installation
or operation of this machine.
TO AVOID SERIOUS PERSONAL INJURY
NEVER Place Hands into Machine Input or Output Openings.
ONLY Properly Trained Personnel Should Use This Equipment.
11. With the grinding auger removed from the machine, push the green start button for grind. CHECK THE
ROTATION OF THE AUGER DRIVE SHAFT; ROTATION MUST BE COUNTER-CLOCKWISE
as indicated by the rotation decal afxed to the grinding bowl. ROTATION MUST ONLY BE
CHECKED WITH THE GRINDING AUGER REMOVED, otherwise serious irreparable damage
may occur to the grinding components.