Display Size | 7 inch |
---|---|
Resolution | 800 x 480 |
FHR Accuracy | ±1 bpm |
Waterproof Probe | Yes |
Alarm Function | Yes |
Display Type | TFT LCD |
FHR Range | 30 to 240 bpm |
TOCO Range | 0 to 100 |
Ultrasound Frequency | 1 MHz |
Printing Speed | 1, 2, 3 cm/min |
Paper Size | 112 mm |
Battery | Rechargeable |
Input Voltage | 100-240 V |
Operating Temperature | 10 to 40°C |
Storage Temperature | -20 to 60°C |
Display | Color TFT LCD |
Covers general safety guidelines, warnings, and cautions for operating the BT-740 patient monitor.
Details specific warnings related to electrical shock hazards associated with the monitor.
Provides crucial warnings and precautions regarding the use and handling of the device's battery.
Outlines environmental conditions to avoid for safe and proper operation of the equipment.
Defines the intended applications and user profiles for the BT-740 patient monitor.
Lists the standard and optional configurations of the BT-740 patient monitor.
Provides a detailed description of the monitor's front view, including labeled components.
Explains the function of the graphic hotkeys displayed on the monitor's main screen.
Details the installation requirements including unpacking, placement, power, and environmental conditions.
Provides instructions on how to connect the BT-740 patient monitor to a power source.
Guides the user through the steps to turn on the BT-740 patient monitor.
Explains fundamental operations like using the control knob, keys, and touch screen.
Describes the two operating modes: Monitoring mode and Demo mode.
Explains how to access and navigate the patient setup menu for managing patient data.
Provides step-by-step instructions for admitting a new patient into the monitor.
Details how to edit patient information such as name, ID, gender, and type.
Guides users on how to select different display formats like Normal, Big ECG, and Big Font.
Describes the appearance and content of various display formats for the monitor.
Categorizes alarms into physiological, technical, and prompt messages.
Explains the priority levels (high, medium, low) assigned to different alarm conditions.
Details the visual and audible methods used by the monitor to alert users to alarms.
Covers setting alarm delay time, reminder signals, and individual parameter alarms.
Highlights safety precautions specific to ECG monitoring, including electrode use and interference.
Details the procedure for setting up and performing ECG monitoring, including lead selection.
Explains how to configure ECG parameters such as HR source, wave gain, and filter mode.
Provides safety guidelines for respiration monitoring, emphasizing electrode placement and cable use.
Covers configuration settings for respiration monitoring, including apnea delay and wave gain.
Details how to adjust the volume for Pulse Rate (PR) sounds.
Explains how to configure alarms for Pulse Rate (PR) parameters.
Outlines safety precautions for SpO2 monitoring, including sensor use and potential interferences.
Guides the user through the process of setting up and starting SpO2 monitoring.
Details how to configure SpO2 settings such as wave speed, mode, and average time.
Provides safety guidelines for Non-Invasive Blood Pressure (NIBP) measurements.
Details the steps for performing NIBP measurements, including preparation and posture.
Explains how to manually set the initial cuff inflation pressure for NIBP measurements.
Guides the user through the process of measuring body temperature with the monitor.
Describes how body temperature is displayed, including channel readings and alarm limits.
Explains how to view historical data trends in a graphical chart format.
Details how to access and browse historical monitoring data in a tabular format.
Provides guidelines for optimal battery life and proper usage of the monitor's battery.
Outlines the steps to check the battery's performance and duration.
Details the recommended methods and agents for cleaning the monitor and its components.
Lists essential checks to perform before using the monitor and periodic safety checks.
Explains the process for calibrating the ECG signals to ensure accuracy.
Details product category, electrical shock, explosion, and liquid inlet protection grades.
Provides technical specifications for ECG, TEMP, RESP, NIBP, and SpO2 monitoring parameters.
Lists physiological alarms, their priority, and causes with corresponding countermeasures.
Details technical alarms, their priority, and causes with suggested solutions.
Specifies electromagnetic emission compliance and guidance for the BT-740.
Details electromagnetic immunity test levels and guidance for the BT-740.