29
Memory
Group 0
Power-On
RST
Buzzer
On
Load On Knob
Update
On Timer
Off
Voltage Auto Range
On
Averaging Filter
2^14
Remote Sense
Off
External Program
Off
Configure Power-On State
The initial Power-On state of the load can be configured by following the steps below:
1. From the SYSTEM menu, select Power-On and press .
2. There are two options:
Rst(Def) Factory Default.
Sav0 Settings before last power up. Recalls the settings saved to “0” memory location.
3. Select the settings you want during power up, and press to save changes.
4. To exit the menu at any time, press twice.
Load On Knob
This setting controls the behavior of the knob.
1. From the SYSTEM menu, select Knob and press .
2. There are two options:
Update(default) Real time update.
Old No update (when turning load ON/OFF, original value before use of rotary knob
will be set)
3. Select the settings you want during power up and press to save changes.
4. To exit the menu at any time, press twice.