85
2) The slew rate specifications are not warranted but are descriptions of typical performance. The actual transition
time is defined as the time for the input to change from 10% to 90%, or vice versa, of the programmed current
values. In case of very large load changes, e.g. from no load to full load, the actual transition time will be larger
than the expected time. The load will automatically adjust the slew rate to fit within the range (high or low)
that is closest to the programmed value.
Model
8620
8622
8624
8625
Input Ratings
Input Voltage
0 120 V
0 500 V
0 120 V
0 120 V
Input
Current
Low
0 48 A
0 10 A
0 60 A
0 72 A
High
0 480 A
0 100 A
0 600 A
0 720 A
Input Power
3000 W
2500 W
4500 W
6000 W
Minimum
Operating
Voltage
Low
0.2 V at 48 A
0.3 V at 10 A
0.18 V at 60 A
0.18 V at 72 A
High
2 V at 480 A
3 V at 100 A
18 V at 600 A
1.8 V at 720 A
CV Mode
Range
Low
0 18 V
0 50 V
0 18 V
0 18 V
High
0 120 V
0 500 V
0 120 V
0 120 V
Resolution
Low
1 mV
High
10 mV
Accuracy
Low
±(0.025%+0.05%FS)
±(0.025%+
0.025%FS)
±(0.025%+0.05%FS)
High
±(0.025%+0.05%FS)
CC Mode
Range
Low
0 48 A
0 10 A
0 60 A
0 72 A
High
0 480 A
0 100 A
0 600 A
0 720 A
Resolution
Low
1 mA
High
10 mA
Accuracy
Low
±(0.25%+0.05%FS)
High
±(0.25%+0.05%FS)
CR Mode
Range
Low
0.01 10 Ω
0.03 10 Ω
0.01 Ω – 10 Ω
0.005 10 Ω
High
10 Ω - 7.5 kΩ
Resolution
16 bit
Accuracy
Low
0.01%+0.08 S
High
0.01%+0.0008 S
CW Mode
Range
3000 W
2500 W
4500 W
6000 W
Resolution
100 mW
Accuracy
0.2% + 0.2%FS