48
7 Specifications
Note: All specifications apply to the unit after a temperature stabilization time of 15 minutes
over an ambient temperature range of 23 °C ± 5 °C. Specifications are subject to change
without notice.
Environmental Conditions:
This power supply is designed for indoor use and operated with maximum relative humidity of
80%.
Model
9201
9202
9205
9206
Output Rating
Voltage
0-60 V
0-60 V
0-60 V
0-150 V
Current
0-10 A
0-15 A
0-25 A
0-10 A
Power
200 W
360 W
600 W
600 W
Line Regulation
Voltage
≤0.01%+5 mV
≤0.01%+8 mV
≤0.01%+15 mV
≤0.01%+15 mV
Current
≤0.05%+4 mA
≤0.05%+6 mA
≤0.1%+10 mA
≤0.05%+10 mA
Load Regulation
Voltage
≤0.01%+8 mV
≤0.01%+8 mV
≤0.01%+15 mV
≤0.01%+15 mV
Current
≤0.05%+6 mA
≤0.05%+6 mA
≤0.1%+10 mA
≤0.05%+10 mA
Ripple and Noise (20Hz-20MHz)
Voltage
≤8 mVpp
≤15 mVpp
≤20 mVpp
≤50 mVpp
Current
≤6 mArms
≤8 mArms
≤15 mArms
≤15 mArms
Programming Resolution
Voltage
1 mV
1 mV
1 mV
1 mV
Current
0.1 mA
0.1 mA
0.1 mA
0.1 mA
Readback Resolution
Voltage
1 mV
1 mV
1 mV
1 mV
Current
0.1 mA
0.1 mA (<10 A)
1 mA (>10 A)
0.1 mA (<10 A)
1 mA (>10 A)
0.1 mA
Programming Accuracy ± (%output+offset)
Voltage
≤0.03%+5 mV
≤0.03%+5 mV
≤0.03%+5 mV
≤0.03%+20 mV
Current
≤0.1%+10 mA
≤0.1%+15 mA
≤0.1%+25 mA
≤0.1%+25 mA
Readback Accuracy ± (%output+offset)
Voltage
≤0.03%+5 mV
≤0.03%+5 mV
≤0.03%+5 mV
≤0.03%+20 mV
Current
≤0.1%+10 mA
≤0.1%+15 mA
≤0.1%+25 mA
≤0.1%+25 mA
w ww . . co m
information@itm.com1.800.561.8187

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BK Precision 9201 and is the answer not in the manual?

BK Precision 9201 Specifications

General IconGeneral
BrandBK Precision
Model9201
CategoryPower Supply
LanguageEnglish

Related product manuals