103
Parameter index
Code Page Name Unit Possible value / Function Factory setting
User
setting
FLOC 61
Forced local reference
nO
AI1
LCC
AIU1
No
Terminal
HMI
Jog dial
nO
FLr
78
Catch on the fly
nO
YES
No
Yes
nO
Fr1
44
60
Reference channel 1
AI1
LCC
Mdb
AIU1
Terminal
HMI
Modbus
Jog dial
Al1
FrH 36
Speed reference
AI1
LCC
Mdb
AIU
Terminal
HMI
Modbus
Jog dial
FrS 55
Rated motor frequency Hz 10 to 400 -
50 or 60 Hz
(to bFr)
FSt 64
Fast stop assignment
nO
L1L
L2L
L3L
L4L
No
L1L: LI1 active low
L2L: LI2 active low
L3L: LI3 active low
L4L: LI4 active low
nO
Ftd 53
Motor frequency threshold Hz 0 to 400 - 50 or 60 Hz
FtH 41
Fan time display 0.01 to 999 ---
HSP
44
76
High speed Hz LSP to tFr - 50 or 60 Hz
HSP2
76
High speed 2 Hz LSP to tFr -
50 or 60 Hz
according to
BFr, max TFr
HSP3
76
High speed 3 Hz as HSp2 as HS2
as HSp2
HSP4
76
High speed 4 Hz as HSp2 as HS2
as HSp2
HSU
40
Display of high speed value - - - - -
InH
81
Detected fault inhibition
assignment
nO
L1H
L2H
L3H
L4H
Non active
L1h: LI1 active high
L2h: LI2 active high
L3h: LI3 active high
L4h: LI4 active high
nO
IPL
80
Input Phase loss -
nO
YES
No
Yes
YES
Ith 80
Motor thermal current A 0.2 to 1.5 -
according to
drive rating
JOG
66
Jog assignment
nO
L1H
L2H
L3H
L4H
No
L1h: LI1 active high
L2h: LI2 active high
L3h: LI2 active high
L4h: LI4 active high
nO
JPF
68
Skip frequency Hz 0 to 400 - 0 Hz