104
Parameter index
Code Page Name Unit Possible value / Function Factory setting
User
setting
LC2
74
2
nd
current limitation
commutation
nO
L1H
L2H
L3H
L4H
L1L
L2L
L3L
L4L
No
L1h: LI1 active high
L2h: LI2 active high
L3h: LI3 active high
L4h: LI4 active high
L1L: LI1 active low
L2L: LI2 active low
L3L: LI3 active low
L4L: LI4 active low
nO
LCr
38
Motor current A - - - -
LFL1
81
4-20 mA loss behaviour
nO
YES
No
Yes
nO
LFr
38
44
60
External reference value - -400 to 400 -0
LIS1 40
State of logic inputs LI1 to LI4 - - - - -
LOC 52
Application Overload threshold % of In 70 to 150 - 90 %
LO1 52
LO1 assignment as r1 as r1 nO
LO1S 52
LO1 status (output active level)
POS
nEG
Positive
Negative
POS
LOS1 40
State of the logic output LO1
and relay R1
-- - - -
LSP
44
75
Low speed Hz 0 to HSP - 0 Hz
LUL 53
Application Underload
threshold
% of In 20 to 100 - 60 %
MPC 58
Motor parameter choice -
nPr
COS
nPr
COS
nPr
MtM
80
Motor thermal state memo -
nO
YES
No
Yes
nO
nC1
84
Com scanner write address
value 1
nC2
84
Com scanner write address
value 2
nC3
84
Com scanner write address
value 3
nC4
84
Com scanner write address
value 4
nCA1
83
Com scanner write address
parameter 1
2135
nCA2
83
Com scanner write address
parameter 2
219C
nCA3
83
Com scanner write address
parameter 3
0
nCA4
83
Com scanner write address
parameter 4