Section 11: BD8 Pre-Installation Checklist
Store Number and Location:
Completed By : Date :
CHECK LIST COMMENTS
1 Do you know exactly where the unit is going to be
installed? The unit is designed to be placed on top of a
counter. Counter location should be near water and ice.
See section 2.4 for equipment dimensions The closer to
the product bags the better. Product lines that run more
than 10’ (3 meters) are not recommended.
2 Counter placement: Ensure there are at least 4 inches of
space on each side and at least 6 inches in back (room
for product installation).
3 Is the unit being installed in close proximity to a sink?
(Needed for water connections.)
4 Are you connecting water to the unit? (If yes, go to
number 5. If no, skip to number 6 and put N/A in the com-
ments.)
5 Have the following requirements been met for water
connection to the unit:
1) Water source needs to set up per local code, and
terminated at the unit with a flexible reinforced water line.
(Water line needs to be at least ½” diameter and termi-
nate at the unit with a 3/8” female compression
connector.)
2) Water pressure needs to be at least 30psi and no more
than 120psi.
3) Adequate backflow prevention installed to comply with
local plumbing codes (requires a licensed plumber).
4) Shut-off valve installed between the water supply and
the unit.