EasyManua.ls Logo

Blodgett BCX14E - Error Codes Manual Control W;Meat Probe.; Error Messages and Relay Behavior

Blodgett BCX14E
85 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B l o d g e t t O v e n
Page
43
BX14E / BCX14E Man Control - Inverter Stored Fault Codes 50817
NOTE:
Oven connected to power, mode switch in "OFF" position, display should read "
0.0
".
PRESS STORED FAULT CODES DISPLAY
FUNC
d 0 0 1
keep pushing until
d 0 0 8
FUNC once
E 0 ? ?
Record Code
FUNC once
d 0 0 8
keep pushing until
d 0 0 9
FUNC once
E
0
?
?
Record Code
FUNC once
d 0 0 9
keep pushing until
d 0 0 1
FUNC once
0. 0
COMPLETED EXIT AT
Motor Inverter Error Codes
E_01
Over current event while at constant speed
E_02
Over current event during deceleration
E_03
Over current event during acceleration
E_04
Over current event during other conditions
E_05
Overload protection
E_07
Over-voltage protection
E_08
EEPROM error
E_09
Under-voltage error
E_11
CPU error
E_22
CPU error
E_12
External trip
E_13
USP
E_14
Ground Fault
E_15
Input over-voltage
E_21
Inverter thermal trip
E_35
Thermistor

Related product manuals