Error Codes
Manual Control W/Meat Probe.
Errors messages
On any Error condition the K1 output relay will de-energize.
Display reads “E r r 2” indicates open or shorted cavity probe, Check for ohm’s @ 75° = 1090Ω
Display reads “E r r 3” indicates open or shorted meat probe (If) it is plugged in at the time check to see if the
meat probe has been activated with/out a meat probe in jack.
Meat probe is 1K check for ohm’s @ 75° = 1090Ω
The top two terminals on the back of the temperature control are the cavity probe location and the bottom
two and the meat probe terminal.