EasyManuals Logo

Blodgett BLCT-61G User Manual

Blodgett BLCT-61G
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #30 background imageLoading...
Page #30 background image
Settings on the Technician Menu
Deliming Settings
The Delime program is used to descale the steam generator. This function is not
used if the oven is connected to a water treatment filter and the water has been
tested to prove it meets the purity requirements but is still recommended to run
every 90 hours.
Starting the Deliming Program
1. On the Technician display, touch Delime.
2. To start the delime program, touch Delime Program.
3. Touch Delime to start the program.
4. A message is displayed asking if the oven is empty. Verify that the oven is
empty, and then select Yes and touch OK.
5. The deliming program starts. The display shows the current step of the process.
6. When the deliming process has finished, the display shows a message
saying “Descale is done”, and an alarm sounds for 5 seconds. Touch OK.
Enabling or Disabling Automatic Deliming
This function is only available for OEM ovens.
1. On the Technician display, touch Delime.
2. Touch Auto delime.
3. Select Yes or No and then touch OK.
Specifying the Deliming Interval
Use this function to specify how often you want the oven to display a message
saying that the oven needs to be delimed.
1. On the Technician display, touch Delime.
2. Touch Delime interval.
3. Slide your finger up or down to select the preferred interval: 30, 60, or 90
hours, and then touch OK.
SERVICE MANUAL 31

Other manuals for Blodgett BLCT-61G

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Blodgett BLCT-61G and is the answer not in the manual?

Blodgett BLCT-61G Specifications

General IconGeneral
BrandBlodgett
ModelBLCT-61G
CategoryOven
LanguageEnglish

Related product manuals