EasyManuals Logo

Blodgett BLCT User Manual

Blodgett BLCT
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #44 background imageLoading...
Page #44 background image
Troubleshooting
Error Code 26
The ClimaOptima sensor signals outside of the active area.
Steps
Check list
Solution
1 Go to the test menu to see which
information the computer displays.
2 Check the cable and the cable plugs
and change the plug if necessary,
and then test if the sensor is working.
3 Check the ClimaOptima sensor in the
test menu, and replace it if necessary,
and then test if the sensor is working.
Error Code 27
ClimaOptima calibration could not be completed. A step took too long.
Steps
Check list
Solution
1 Go to the test menu to see which
information the computer displays.
2
The jet may be clogged & check that the
Restart the calibration
steam jet solenoid is working properly.
process. The oven must be
cold.
SERVICE MANUAL 45

Other manuals for Blodgett BLCT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Blodgett BLCT and is the answer not in the manual?

Blodgett BLCT Specifications

General IconGeneral
BrandBlodgett
ModelBLCT
CategoryOven
LanguageEnglish

Related product manuals