Troubleshooting
Error Code 34
The water pressure is too low.
Steps
Check list
Solution
1
Check that the water is turned on.
Clean the solenoid valve
filter.
2
Check that the water pressure is at least
Change the sensor.
36 psi.
Error Code 37
While running the CombiWash program, the oven could not cool down to set point.
Steps
Check list
Solution
1
Check that the jet in the oven chamber is
Run CombiWash step 0
not clogged and working.
before using the oven.
Error Code 38
CombiWash was interrupted while there was still detergent in the oven chamber.
Steps
Check list
Solution
1
-
Run CombiWash step 0
before using the oven.
Error Code 39
There is insufficient memory to run the selected operation.
Steps
Check list
Solution
1
-
If possible, delete some
HACCP files.
SERVICE MANUAL 47