INSTALLATION
1 --- 2
RATINGS -- GAS APPLIANCES -- BC14G/AA
Gas Type Gas Input Voltage Phase Amps Motor
Natural Steam --- 55,000 BTU/Hr
208-240 1 15 1/2HP 208-240VAC, 50/60 Hz
ot
r --- 65,000
r
Total --- 115, 000 BTU/Hr
120 1 15 1/2HP 208-240VAC, 50/60 Hz
Propane Steam --- 48,000 BTU/Hr
208-240 1 15 1/2HP 208-240VAC, 50/60 Hz
ot
r --- 65,000
r
Total --- 113, 000 BTU/Hr
120 1 15 1/2HP 208-240VAC, 50/60 Hz
3/4” FNPT connector for all U. S. and Canadian installations
TABLE 4
RATINGS -- GAS APPLIANCES -- BC14GDS/AA
Gas Type Gas Input Voltage Phase Amps Motor
Natural 65,000 BTU/Hr
208-240 1 15 1/2HP 208-240VAC, 50/60 Hz
120 1 15 1/2HP 208-240VAC, 50/60 Hz
Propane 65,000 BTU/Hr
208-240 1 15 1/2HP 208-240VAC, 50/60 Hz
120 1 15 1/2HP 208-240VAC, 50/60 Hz
3/4” FNPT connector for all U. S. and Canadian installations
TABLE 5
GAS PRESSURE - - BC14G/AA and BC14GDS/AA
Gas
Inlet
Orifice Size at Sea Level Manifold Pressure
Type Pressure
Hot Air Steam Hot Air Steam
Natural 7 --- 1 4” W. C . .0531” dia .042” dia 3.5” W.C. 3.5” W.C.
Propane 12---14” W.C. .032” dia .026” dia 10.0” W.C. 10.0” W.C.
TABLE 6