BC14E
9 --- 1
INSTALLATION SPECIFICATIONS
NOTE: Electrical and water connections must be
performed by a qualified installer only.
MAXIMUM SHELF LOADING
BC14E 100 lbs (45.5 Kg)
TABLE 1
PLUMBING SPECIFICATIONS -- B C14E/AA
Water
Water Pressure 30 PSI (207 k Pa) minimum
50 PSI (345 kPa) maximum
Water Connection 3/4” Hose Hot a nd Cold Water
Water Regulator Setting Preset to 20 PSI (138 kPa)
Drainage Atmospheric Vented Drain
Drain Connection 2.00” (50.8mm) Copper
Avg Water Drain Temp. Approximately 160 _F(71_C)
TABLE 2
PLUMBING SPECIFICATIONS -- B C14EDS/AA
Water
Water Pressure 30 PSI (207 k Pa) minimum
50 PSI (345 kPa) maximum
Water Connection 3/4” Hose Cold Water
Water Regulator Setting Preset to 20 PSI (138 kPa)
Drainage Atmospheric Vented Drain
Drain Connection 2.00” (50.8mm) Copper
Avg Water Drain Temp. Approximately 160 _F(71_C)
NOTE: For steam requirements see page 9 ---4 STEAM CONNECTION for the BC14EDS