Operation
13
Blodgett IQT Phase IV Control
Programming the Timing Mode:
There are 3 options for timing mode: Straight, Flex
and Sensitivity.
1. The t op display reads t C --- 1 . The bottom dis -
play gives the current timing mode. Press the
TOGGLE/CLEAR KEY (11) to toggle between
St, FL and SEns.
2. If straight or flex are selected press the SCAN
KEY (15) to advance the programming mode
to PreAlarms.
3. If sensitivity is selected press the SCAN KEY
(15) and continue with Steps 4---5.
NOTE: Sensitivity adjusts the cook time to
compensate for any difference be-
tween the setpoint and actual temper-
ature. The lower the sensitivity value
the shorter the time adjustment.
4. The top display reads S E --- 1 .Usetheproduct
keys to enter the desired sensitivity from 0-9.
5. Press the SCAN KEY (15) to advance the pro-
gramming mode to PreAlarms.
Programming the PreAlarms:
A PreAlarm is an alarm that sounds during the
cook cycle. PreAlarms can be used to alert the op -
erator that the product needs to be turned or
stirred, etc. Up to three PreAlarms can be pro-
grammed for each product.
1. The top display reads A1__.(The__indicate
the product key) The bottom display gives the
alarm time. Use the product keys to enter the
desired time for the first alarm. Press the EN-
TER KEY (14) to enter the PreAlarm time.
NOTE: PreAlarm times are measure d from th e
end of the total cook time. For example
if the total cook time is 30:00 and a
PreA larm o f 5 : 00 is e nt e re d, the ala rm
will sound 25 minutes into the cook
cycle. If a PreAlarm of 0:00 is entered,
no additional PreAlarms may be pro-
grammed for the selected product key.
2. Press the SCAN KEY (15).
3. The top display reads AUTo. The bottom dis-
play reads either YES or no.Pressthe
TOGGLE/CLEAR KEY (11) to toggle between
YES and no. Press the SCAN KEY (15) to enter
the PreAlarm type.
NOTE: An auto PreAlarm sounds for approxi-
mately 5 seconds, then shuts off auto-
matically. For manual PreAlarms the
operator must press the product key
to silence the alarm.
4. The top display reads A2__. Repeat s teps 1---3
for the second and third PreAlarm. When all
PreAlarms have been entered the control ad-
vances to programming the head count.
Programming the Head Count:
1. The t op display reads HEAd. The bottom dis -
play gives the current number of heads pro-
grammed for this product key. Use the prod-
uct keys to enter the desired number of heads
from 1-99.
2. Press the SCAN KEY (15). The programming
forthisrecipeisnowcomplete.
Exiting the programming mode:
1. The top display reads Prod. Press the PROG KEY
(10). The co ntrol returns to operating mode.

Other manuals for Blodgett Mark V

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Blodgett Mark V and is the answer not in the manual?

Blodgett Mark V Specifications

General IconGeneral
ModelMark V
ManufacturerBlodgett
CategoryOven
Temperature Range200°F - 500°F (93°C - 260°C)
ConstructionStainless Steel

Related product manuals