JUST POWER ON 65
7.2 Power On
Step 1: Switch on the DC circuit breakers on EP760.
Step 2: Switch on the DC circuit breakers on B500 battery packs. Press and hold the
power button on any B500 till the indicator on the button light up green.
Step 3: Wait for about 40 seconds till the inverter indicator keeps steady green.
Step 4: Switch on the AC circuit breakers connected to the inverter GRID terminal.
Step 5: Power on the system via BLUETTI App. For details, please refer to BLUETTI
App Instructions.
Step 6: Check the output voltage of BACKUP terminal.
Step 7: Switch on the AC circuit breakers connected to the inverter BACKUP
terminal.
Step 8: Check the EP760 system status through the App.
7.3 Power Off
Step 1: Turn off the AC power on BLUETTI App.
Step 2: Switch off the AC circuit breakers connected to the inverter GRID and
BACKUP terminals.
Step 3: Switch off the inverter PV breaker.
Step 4: Press the power button on any B500 till the indicator on the button flashes
green.
Step 5: The indicator continues to flash.
Step 6: When the indicator is off, B500 battery packs turn off.
Step 7: Switch off main switches for all B500 and the system powers off.
Warning
There is still residual voltage after the EP760 ESS is powered off,
which may cause electric shock or burns. Please wait at least 30
minutes before operating the system.
Warning