7
2. Gas interface
Cutting gas interface
Nozzle cooling gas
connection
Installation connection: cutting gas 1, nozzle cooling gas 2
Notice:
The maximum pressure of cutting gas is 25bar (2.5Mpa).
The cutting gas quality shall meet the requirements of gas quality in accordance with ISO 8573-1:2010:
solid particles - class 2, water - class 4, oil - class 3. The purer the cutting gas, the longer the life of the
protective lens.
The cutting gas pipe diameter (outer diameter) is 10mm, and the nozzle cooling gas pipe diameter
(outer diameter) is 8mm.