BodorWelder Fiber Laser User Manual-V1.1
Bodor Inc.
9- Fault list
The alarm points for the laser are as follows:
Serial
Number
Alarm
Code
Fault Name
Fault Cause
Remark
1
ER-001
Temperature
alarm
The laser
overtemperature is
faulty
The internal temperature fault
of the laser, the long-term
operation of the laser will also
lead to the accumulation
temperature is too high, and the
light needs to be stopped and
cooled before it can be used
again.
2
ER-002
Humidity alarm
Excessive internal
humidity
The internal humidity of the
laser exceeds the threshold.
Check whether the ambient
humidity is too high
3
ER-003
Forward alarm
to PD
The internal optical path of
the laser is faulty
The causes of this failure are:
low modulation frequency, low
peak power, low cutting power,
and other operations that may
cause low output power of the
laser.
4
ER-004
Spatial PD
alarm
The internal optical path of
the laser is faulty
The possible causes are as
follows: The optical fiber is
damaged or light leaks
5
ER-005
Overcurrent
alarm
The current of the driver
board is too large
The laser driver is abnormal.
Contact the after-sales service
5, due to the different equipment configuration (wire feeding machine differences) and welding methods (wire
feeding speed, air pressure, degree of deflection, welding Angle) used by different customers, this data is for
reference only;