19
Remarks
Time Interval =0 to turn off this function
Time Interval =[120-65535] (unit: second)
Example: 000000PTI300, PT600X will take photos every 300 seconds
NOTE
This feature is valid when PT600X’s firmware version is 1.40 above
Set Alarm Action
Command
<password>AN<Index1>’#<Index2>,’,<Index3>,’#<Index4>’
Remarks
Index1= 1 mean NO.1 Action. (it can be 1-5)
Index2=OPC2,1 means trigger output 2 on
OPC3,1 means trigger output 3 on
TEL13112345678 means trigger this TEL command to call 13112345678
NOTE: any other command can be used at index2
Index3=Time (Unit: second)
NOTE: If you want to automatically close the above alarm or trigger another alarm in few
seconds, please input the time at index3, and also set below index4.
Index4=OPC2,0 means close output 2
OPC3,0 means close output 3
TEL13012345678 means trigger this TEL command to call 13012345678
NOTE: Any other command can be used at index4
Set Alarm
Command
<password>SAL<Alarm type><Index1><Index2><Index3><Index4><Index5>
Remarks
Alarm type =IN1/IN2/IN/IN4/IN5/SPD/GEO/MLA/SKA/LPA/IU1/IU2/IU3/IU4/IU5
Index1=1, to alert on platform
=0, do not alert on platform
Index2=1, to send alert SMS
=0, do not send alert SMS
Index3=1, to call the preset SOS phone number
=0, do not call the preset SOS phone number
Index4=1, to take photo
=0, do not take photo
Index5=Action No.
(plea NOTE: if you want to trigger above alarm action, then please use related Action No. what
you set in Index1 in above AN command
Default Setting:
000000SALIN11110
000000SALIN21110
000000SALIN31110
000000SALIN40000
000000SALIN50000
Example
000000SALIN11110
That means, when input 1(SOS key) is pressed, PT600X will send SOS alarm on platform, send
alarm SMS to SOS number, call to SOS number, but do not take photo