AD alarm
Command
<password>AD<index1><index2><Parameter>,<alarm name>,<index3>
Remarks
Index1 =14 means AD1AD4
Index 2 =[</>]
Parameter=[0~100] (unit: %)
Alarm name = default is AD1 alarm, if you use ―fuel alarm‖ at here, you will get alarm fuel alarm
SMS contents.
Index3 = 1 means input1
2 means input2
3 means input3
4 means input4
5 means input5
Example
000000AD1<10,Fuel Low,4
After you connect fuel sensor to PT600X AD1 wire, PT600X will send Fuel Low alarm SMS to SOS
number when tracker get AD1 data <10%, but this alarm is effective only when input4 on (if you
connect input4 to car ignition, then it means car ignition on).
NOTE: if your fuel sensor keep working even when car ignition off, you don’t need to set index3 as
input4 here.
Set Analog Voltage
Command
<password>AV<AD Port><min voltage of sensor>,<max voltage of sensor>,24
Remarks
AD Port=14 means AD1AD4
Min voltage of sensor=input your sensor min voltage at here
Max voltage of sensor=input your sensor max voltage at here, it can’t be over the max voltage of
tracker support.
NOTE
If your analog sensor max voltage is not 6V, then you need to do this setting, to let tracker know
what is your sensor voltage specification
Shake Alarm(or Move Alarm)
Command
<password>SKA<index>
Remarks
Index = 1, to send shake alarm SMS to SOS number when PT600X shakes
= 0, not to send shake alarm SMS to SOS number when PT600X shakes.
NOTE
PT600X with built-in motion sensor to support this function.
Define motion sensor sensitivity