49
Status
The Status selection for the power amplifier provides real-time status, such as whether
the amplifier is operating in 2-channel mono or single-channel bridged mode, LEDs for
thermal protection and clipping, a real-time reading of the appliance’s temperature, and
indicators for the amplifier’s standby and mute status. Note that the number of channels
that appear depends on whether the amplifier is operating in 2-channel mono or single-
channel bridged mode.
Table 20. Standby Settings
Enable Enables or disables the standby feature for the amplifier.
Threshold Amp AB Sets the threshold level for channels A/B.
I
f the signal level remains below this level for 200 sec-
onds or longer, the amplifier is put into low power
St
andby mode. Normal operation will resume (within
one second) once a signal is received that exceeds this
level.
The range is -144 to +24 dB.
Status Indicates if channels A/B
a
re in Standby mode (On) or
not (Off).