ACTIVE CUBE
Operating Instructions
Frequency inverter 230 V / 400 V
0.25 kW ... 132 kW

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI ACTIVE Cube ACU 401-33 and is the answer not in the manual?

BONFIGLIOLI ACTIVE Cube ACU 401-33 Specifications

General IconGeneral
BrandBONFIGLIOLI
ModelACTIVE Cube ACU 401-33
CategoryInverter
LanguageEnglish

Summary

2 General Safety Instructions and Information on Use

2.4 Residual Risks

Identifies potential hazards that cannot be eliminated despite safety-compliant design, including electrical, electrostatic, and thermal risks.

2.7 Directives and Guidelines to be Adhered to by the Operator

Outlines directives operators must follow, including ensuring accessibility of regulations and compliance with country-specific laws.

2.9 OperatorsOperating Staffs Responsibilities

Defines responsibilities for staff selection, qualification, and general work safety to prevent accidents and damage.

2.11 Safety Instructions on Function Safe Torque Off (STO)

Provides safety instructions for the STO function, emphasizing proper installation and qualified commissioning.

4 Technical Data

4.3 ACU 201 (0.25 to 1.1 kW, 230 V)

Presents detailed technical data for ACU 201 inverters from 0.25 to 1.1 kW at 230 V, covering motor and mains sides.

4.4 ACU 201 (1.5 to 3.0 kW, 230 V)

Presents detailed technical data for ACU 201 inverters from 1.5 to 3.0 kW at 230 V, including mechanics and ambient conditions.

4.5 ACU 201 (4.0 to 9.2 kW, 230 V)

Presents detailed technical data for ACU 201 inverters from 4.0 to 9.2 kW at 230 V, covering output and input sides.

4.6 ACU 401 (0.25 to 1.5 kW, 400 V)

Presents detailed technical data for ACU 401 inverters from 0.25 to 1.5 kW at 400 V, including fuses and dimensions.

4.7 ACU 401 (1.85 to 4.0 kW, 400 V)

Presents detailed technical data for ACU 401 inverters from 1.85 to 4.0 kW at 400 V, including mechanics and output current.

4.8 ACU 401 (5.5 to 15.0 kW, 400 V)

Presents detailed technical data for ACU 401 inverters from 5.5 to 15.0 kW at 400 V, including ambient conditions and output current.

4.9 ACU 401 (18.5 to 30.0 kW, 400 V)

Presents detailed technical data for ACU 401 inverters from 18.5 to 30.0 kW at 400 V, covering output current and ambient conditions.

4.10 ACU 401 (37.0 to 65.0 kW, 400 V)

Presents detailed technical data for ACU 401 inverters from 37.0 to 65.0 kW at 400 V, including mechanics and output current.

4.11 ACU 401 (75.0 to 132.0 kW, 400 V)

Presents detailed technical data for ACU 401 inverters from 75.0 to 132.0 kW at 400 V, including mechanics and output current.

5 Mechanical Installation

5.1 ACU 201 (up to 3.0 kW) and 401 (up to 4.0 kW)

Details the standard mounting dimensions and installation possibilities for ACU 201 (up to 3.0 kW) and 401 (up to 4.0 kW).

5.2 ACU 201 (4.0 to 9.2 kW) and 401 (5.5 to 15.0 kW)

Details the standard mounting dimensions and installation possibilities for ACU 201 (4.0 to 9.2 kW) and 401 (5.5 to 15.0 kW).

5.3 ACU 401 (18.5 to 30.0 kW)

Details the standard mounting dimensions and installation possibilities for ACU 401 (18.5 to 30.0 kW) frequency inverters.

6 Electrical Installation

6.4 Connection of Unit

Details conductor cross-section dimensioning according to EN61800-5-1 and provides typical cross-sections for various connections.

6.6 Control Terminals

Explains the configuration of control hardware and software for free assignment of functions to control terminals.

6.7 Configurations Overview

Presents a table summarizing possible combinations of functions and control methods available in different configurations.

7 Control Unit KP500

7.4 Parameter Menu (PARA)

Details how to select, edit, and save parameters, including navigating through parameter numbers and operation modes.

8 Commissioning of the Frequency Inverter

8.2 Setup Using the Control Unit

Guides the user through the setup process using the control unit, covering parameter settings and guided commissioning.

8.3 Check Direction of Rotation

Details the procedure for checking and correcting the motor shaft's direction of rotation after installation.

9 Inverter Data

9.7 Configuration

Explains Configuration 30's role in assigning functions to control inputs/outputs and software functions.

10 Machine Data

10.1 Rated Motor Parameters

Instructs to set rated parameters according to the motor's rating plate for control functions and methods.

12 Operational Behavior

12.1 Starting Behavior

Details parameterization of the 3-phase machine's starting behavior, including magnetization and IxR compensation.

12.2 Stopping Behavior

Defines the stopping behavior of the 3-phase machine using Operation mode 630, selectable via logic signals.

13 Error and Warning Behavior

14 Reference Values

15 Control Inputs and Outputs

15.1 Multi-Function Input MFI1

Describes MFI1's configuration as voltage, current, or digital input, linking to various software functions via Operation mode 452.

15.2 Multi-Function Output MFO1

Explains MFO1's configuration as digital, analog, or repetition frequency output, linked via parameters and Operation mode 550.

15.3 Digital Outputs

Details the selection of functions for digital outputs and relay output, depending on the parameterized configuration.

15.4 Digital Inputs

Explains adapting control signals to software functions via parameterizable inputs, allowing flexible use of digital signals.

16 Vf-Characteristic

17 Control Functions

17.1 Intelligent Current Limits

Sets current limits to avoid inadmissible load and prevent fault switch-off, extending the current controller's capability.

17.3 Technology Controller

Provides PID controller functionality for applications like pressure, volume flow, or speed control without extra components.

17.4 Functions of Sensorless Control

Includes additional functions like Slip Compensation and Current Limit Value Controller that supplement V/f characteristic behavior.

17.5 Functions of Field-Orientated Control

Covers control functions based on cascade control and machine model calculation, including Current Controller and Torque Controller.

18 Special Functions

18.4 Brake Chopper and Brake Resistance

Describes the brake chopper transistor and external brake resistor connection, including trigger threshold settings.

18.5 Motor Protection

Covers monitoring mechanisms for recognizing thermal overload and protecting the motor, including motor protection switch.

20 Error Protocol

20.1 Error List

Provides a chronological list of the last 16 fault messages, including error codes and their meanings.

21 Operational and Error Diagnosis

22 Parameter List

22.2 Parameter Menu (PARA)

Provides a structured list of parameters organized by function category, including setting ranges and chapter references.