ACTIVE CUBE
Operating Instructions
Frequency inverter 230 V / 400 V
0.25 kW ... 132 kW

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI ACTIVE Cube ACU 401-45 and is the answer not in the manual?

BONFIGLIOLI ACTIVE Cube ACU 401-45 Specifications

General IconGeneral
BrandBONFIGLIOLI
ModelACTIVE Cube ACU 401-45
CategoryInverter
LanguageEnglish

Summary

General safety instructions and information on use

Safety and warning signs at frequency inverter

Instructs users to comply with and not remove safety information and danger warnings provided on the inverter.

Warning information and symbols used in the user manual

Explains hazard classes (DANGER, WARNING, CAUTION, NOTE) and symbols used for important safety information.

Operatorsoperating staffs responsibilities

Outlines responsibilities for staff selection, qualification, and general work safety when handling the frequency inverter.

Safety Instructions on Function Safe Torque Off (STO)

Provides safety instructions for the STO function, emphasizing proper installation and qualification by staff.

Scope of Supply

Technical Data

ACU 201 (0.25 to 1.1 kW, 230 V)

Presents detailed technical data for ACU 201 frequency inverters rated from 0.25 to 1.1 kW at 230 V.

ACU 201 (1.5 to 3.0 kW, 230 V)

Provides technical specifications for ACU 201 frequency inverters in the 1.5 to 3.0 kW range at 230 V.

ACU 201 (4.0 to 9.2 kW, 230 V)

Lists technical data for ACU 201 frequency inverters covering the 4.0 to 9.2 kW power range at 230 V.

ACU 401 (0.25 to 1.5 kW, 400 V)

Details technical specifications for ACU 401 frequency inverters from 0.25 to 1.5 kW at 400 V.

ACU 401 (1.85 to 4.0 kW, 400 V)

Provides technical data for ACU 401 frequency inverters in the 1.85 to 4.0 kW power range at 400 V.

ACU 401 (5.5 to 15.0 kW, 400 V)

Lists technical specifications for ACU 401 frequency inverters from 5.5 to 15.0 kW at 400 V.

ACU 401 (18.5 to 30.0 kW, 400 V)

Details technical data for ACU 401 frequency inverters in the 18.5 to 30.0 kW range at 400 V.

ACU 401 (37.0 to 65.0 kW, 400 V)

Presents technical specifications for ACU 401 frequency inverters covering 37.0 to 65.0 kW at 400 V.

ACU 401 (75.0 to 132.0 kW, 400 V)

Lists technical data for ACU 401 frequency inverters in the 75.0 to 132.0 kW range at 400 V.

Mechanical Installation

ACU 201 (up to 3.0 kW) and 401 (up to 4.0 KW)

Describes standard installation dimensions and mounting for ACU 201 and 401 inverters up to 3.0/4.0 kW.

ACU 201 (4.0 to 9.2 kW) and 401 (5.5 to 15.0 kW)

Details standard installation dimensions and mounting for ACU 201 (4.0-9.2 kW) and 401 (5.5-15.0 kW) inverters.

ACU 401 (18.5 to 30.0 kW)

Provides standard installation dimensions and mounting information for ACU 401 inverters from 18.5 to 30.0 kW.

ACU 401 (37.0 to 65.0 kW)

Describes standard installation dimensions and mounting for ACU 401 inverters in the 37.0 to 65.0 kW power range.

ACU 401 (75.0 to 132.0 kW)

Details standard installation dimensions and mounting for ACU 401 inverters from 75.0 to 132.0 kW.

Electrical Installation

Connection of Unit

Covers dimensioning of conductor cross-sections and typical cross-sections for mains and motor connections.

Connection of types

Illustrates mains and motor connection diagrams for ACU 201 and 401 series inverters across different power ratings.

Control Terminals

Describes control terminals and their functions, including wiring guidelines and parameter settings for configurations.

Control Unit KP500

Actual Value Menu (VAL)

Details how to display and navigate through various actual values of the frequency inverter using the control unit.

Parameter Menu (PARA)

Explains how to display, edit, and adjust parameter values within the control unit's parameter menu.

Copy Menu (CPY)

Describes the function for copying parameter values between the control unit and the frequency inverter.

Reading Data from Control Unit

Explains how to transmit parameter values from the control unit to the frequency inverter or vice versa.

Control Menu (CTRL)

Details functions available in the CTRL menu for easier commissioning and direct control of the inverter.

Controlling the Motor via the Control Unit

Explains how to control the connected motor's speed and direction using the control unit and digital inputs.

Commissioning of the Frequency Inverter

Switching on Mains Voltage

Provides crucial safety checks before switching on mains voltage to the frequency inverter.

Setup Using the Control Unit

Guides the user through the guided commissioning procedure for parameter setup and application.

Check direction of rotation

Details the procedure for checking and correcting the motor's direction of rotation after installation.

Speed sensor

Explains how to connect and configure speed sensors (incremental, encoders) for speed control.

Set-up via the Communication Interface

Describes parameter setting and commissioning using optional communication interfaces.

Inverter Data

Configuration

Details how Configuration 30 determines control input/output assignments and software functions.

Machine Data

Rated Motor Parameters

Instructs on setting rated motor parameters from the rating plate for control functions and methods.

Speed Sensor 1

Details the connection and configuration of speed sensor 1 for control functions and methods.

Sensor evaluation

Explains sensor evaluation accuracy levels (single, double, quadruple) for TTL and HTL sensors.

Operational Behavior

Error and warning behavior

Reference Values

Control Inputs and Outputs

Control Functions

Error Protocol