Via parameter Operation mode 435, the drive is configured as a master drive or
slave drive.
Operation mode 435
Function
0 -
Off
The traverse function is deactivated.
1 -
Master Drive
Operation as master drive.
2 -
Slave Drive
Operation as slave drive.
For traverse mode, the reference value source is selected via parameter Reference
frequency 48.
Traverse mode becomes active as soon as the Reference frequency 48
is reached for
the first time. This frequency is reached via the values for Acceleration (clockwise)
420 and Acceleration Anticlockwise 422 and Deceleration (clockwise) 421
and
Deceleration anticlockwise 423. In shot-effect mode, the values for Acceleration
Time
436 and Deceleration Time 437 are active.
The frequency range for shot-effect mode is limited by the Minimum frequency 418
and the Maximum frequency 419.
During traverse operation, the configured traverse parameter values cannot be
changed.
The source of the handshake signal is selected via Handshake Traverse Function 49.
06/13 Operating Instructions ACU 255

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI ACTIVE Cube ACU 401-33 and is the answer not in the manual?

BONFIGLIOLI ACTIVE Cube ACU 401-33 Specifications

General IconGeneral
BrandBONFIGLIOLI
ModelACTIVE Cube ACU 401-33
CategoryInverter
LanguageEnglish

Related product manuals