“TYPE B23P” installations
b
WARNINGS
Multidea Evo appliances are equipped with a flue exhaust sensor, which in the event of anomalous increases in flue
temperatures, shuts down the appliance.
Connect the condensate collection syphon to a clear water drain.
Drain pipelines that are not insulated constitute a potential hazard.
The flue must be correctly sized for condensing boilers and must be fitted with a condensate drain. Inadequate
or incorrectly sized flue ducts and condensate drains can cause problems with combustion parameters and
excessive noise.
IT IS STRICTLY PROHIBITED to seal off or partially obstruct the ventilation apertures of the installation room and the
appliance.
eco
Esc
menu
ok
Monday, 24 September 2012
09.37
eco
Esc
menu
ok
Monday, 24 September 2012
09.37
SF
AR2
SF
AR2
SF
AR2
SF
AR2
eco
Esc
menu
ok
Monday, 24 September 2012
09.37
eco
Esc
menu
ok
Monday, 24 September 2012
09.37
YES YES NO NO
“TYPE C” installations
COAXIAL WALL-MOUNTED FLUE EXHAUST KIT Ø 80/125 mm
This kit enables air intake and flue exhaust mounted on the wall by
means of a coaxial system.
SPLIT EXHAUST/INTAKE DUCT KIT Ø 80 mm
This kit enables separation of the flue exhaust and air intake ducts.
The terminals can be inserted in special flue lines designed for this
purpose, or to remove flue or collect air directly from the wall-mount-
ed system. The exhaust line diameter envisaged on all boilers is Ø
80mm. Depending on the type of appliance supplied, the kit will be
supplied complete with suitable reducer fittings.
The minimum pipe length must be at least 0.5 m, while the maxi-
mum total of sections a + b, obtainable with the use of extensions
must not exceed the maximum linear length specified in the table
“TECHNICAL DATA” page 8.
Bends with Ø 80 mm at 90° and 45° are also available, which reduce
the overall maximum pipe length by:
-
0.9 metres when using 45° bends
-
1.65 metres when using 90° bends
90°
45°
C43
C5
3
intake
exhaust
Ø 80/125
953
C13
- 26 -