Page 8 3BE390691NM – 10/10
BONNET GRANDE CUISINE
Registered Office:
Rue des Frères Lumière - Z.I Mitry Compans
77292 MITRY MORY Cedex
4. CHANGING THE EQUIPMENT FROM ONE GAS TO ANOTHER
Generalities:
In the following chapters, the different gases are referenced by their international codification:
G 20
NATURAL GAS Group H, (Methane, Lacq gas).
G 25
NATURAL GAS Group L, (Type Groningue gas).
G 30
BUTANE
G 31
PROPANE
4.1 LIST OF AUTHORISED GASES/PRESSURE ACCORDING TO CATEGORIES AND COUNTRIES
Countries Category Gases Pressures (mbar)
Austria
I
2H
G20 20
I
3B/P
G30 and G31 50
I
3P
G31 50
Finland - Denmark
I
2H
G20 20
Sweden – Norway
I
3B/P
G30 and G31 30
Czech Republic
I
2H
G20 20
I
3B/P
G30 and G31 30
I
3+
G30 / G31 28-30 / 37
I
3P
G31 37 et 50
Spain
I
2H
G20 20
United Kingdom
I
3+
G30 / G31 28-30 / 37
I
3P
G31 37 et 50
Germany G20 20
Luxemburg
I
2ELL
G25 20
I
3B/P
G30 and G31 30
I
3P
G31 50
Switzerland
I
2H
G20 20
I
3B/P
G30 and G31 50
I
3+
G30 / G31 28-30 / 37
I
3P
G31 37 et 50
Greece
I
2H
G20 20
Italy
I
3B/P
G30 and G31 30
I
3+
G30 / G31 28-30 / 37
I
3P
G31 37
Ireland
I
2H
G20 20
Portugal
I
3+
G30 / G31 28-30 / 37
I
3P
G31 37
Netherlands
I
2L
G25 25
I
3B/P
G30 and G31 30
I
3P
G31 50
France G20 20
I
2Esi
G25 25
I
3+
G30 / G31 28-30 / 37
I
3P
G31 37 et 50
Belgium
I
2E(s)B
G20 / G25 20 / 25
I
3+
G30 / G31 28-30 / 37
I
3P
G31 37