36
Electrical connection
•Theinstallationofthisapplianceandtheconnectiontotheelectricalnetworkshouldbeentrus-
ted only to an electrician perfectly to the fact of the normative regulations and which respects
them scrupulously.
•Protectionagainstthepartsundertensionmustbeensuredafterthebuilding-in.
•Thedataofconnectionnecessaryareonthestickersplaceonthehobcasingnearthecon-
nection box.
•Theconnectiontothemainmustbemadeusinganearthedplugorviaanomnipolarcircuit
breakingdevicewithacontactopeningofatleast3mm.
•Theelectricalcircuitmustbeseparatedfromthenetworkbyadapteddevices,forexample:
circuit breakers, fuses or contactors.
•Iftheapplianceisnotttedwithanaccessibleplug,disconnectingmeansmustbeincorporated
in the fixed installation, in accordance with the installation regulations.
•Theinlethosemustbepositionedsothatitdoesnottouchanyofthehotpartsofthehoboroven.
Caution!
Thisappliancehasonlytobeconnectedtoanetwork230V~50/60Hz.Connectalwaystheearth
wire.Respecttheconnectiondiagram.Theconnectionboxislocatedunderneathatthebackof
the hob casing. To open the cover use a medium screwdriver. Place it in the slits and open the
cover.
*calculatedwiththesimultaneousfactorfollowingthestandardEN60335-2-6/1990
We cannot be held responsible for any incident resulting from incorrect connection or
which could arise from the use of an appliance which has not been earthed or has
been equipped with a faulty earth connection.
Mains Connection Cable diameter Cable Protection
calibre
230V~50/60Hz(BE) 1Phase+N 3x2.5mm² H05VV–F 25A*
H05RR–F
400V~50/60Hz(NL) 2Phase+2N 5x2.5mm² H05VV–F 2x16A*
H05RR–F
Connection of the hob
For the various kinds of connection, use the brass bridges which are in the box next the terminal.
Monophase 230V~1P+NPutthe1stbridgebetweenterminal1and2,the2ndbetween4and5.
Attachtheearthtotheterminate“earth”,theneutralNtoterminal4or5,thePhaseLtooneof
theterminals1or2.
Biphase 400V~2P+NPutthe1stbridgebetweenterminal4and5.
Attachtheearthtotheterminate“earth”,theneutralNtoterminal4or5,thePhaseL1tothe
terminals1andthePhaseL2totheterminal2.
Caution! Be careful that the cables are correctly engaged and tightened.