EasyManua.ls Logo

Bosch 15 SEER2 Series - 4.3 Location Restrictions

Bosch 15 SEER2 Series
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
| 15
Installation Instructions
Bosch 15 SEER2 Inverter Ducted Packaged Heat Pump - BTC 761701319 A (12.2022)
Units should be elevated 3-12 inches above the pad or rooftop,
depending on local weather. This additional height will allow
drainage of snow and will permit condensate water to drain
when the unit is in defrost mode. Ensure that drain holes in
unit base pan are unobstructed, preventing drainage of defrost
water (See Figure 13).
If possible, avoid locations that are prone to snow drifts. If not
possible, a snow drift barrier should be installed around the
unit to prevent a build-up of snow on the sides of the unit.
Ensure that Condensate Drain side is pitched lower than the
opposite side (see Figure 10).
Figure 10
0˘h≤25mm(1°)
h
Condensate drain side
Figure 11
Min. 12" to
Shrubbery
Avoid Install
Near Bedrooms
Min. 60" Unrestricted
Min. 12"
Shrubber
y
A minimum clearance of 24" should be maintained adjacent to
all access/service panels. Refer to local code requirements for
additional clearance requirements.
Figure 12
Min. 24" to
Shrubbery
Min. 12" to
Shrubbery
Access Panel
Supply Air Duct
Figure 13
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
Min 12"
Snow
barrier
3- 12" Elevation
Snow legs
pad
Insulation Layer
Corrosive Environment
Exposure to a corrosive environment may shorten the life of the
equipment, corrode metal parts, and/or negatively aff ect unit
performance. Corrosive elements include, but are not limited to: sodium
chloride, sodium hydroxide, sodium sulfate, and other compounds
commonly found in ocean water, sulfur, chlorine, fl uorine, fertilizers,
and various chemical contaminants from industry/manufacturing plants.
If installed in areas which may be exposed to corrosive environments,
special attention should be given to the equipment placement and
maintenance.
Lawn sprinklers/hoses/waste water should not spray directly
on the unit cabinet for prolonged periods of time.
In coastal areas: locate the unit on the side of the building or
roof away from the waterfront.
Fencing or shrubbery may provide some shielding protection
to the unit, however minimum unit clearances must still be
maintained.
Every three months, wash the outdoor coil and any exposed
cabinet surfaces.

Related product manuals