| 41
Installation Instructions
Bosch 15 SEER2 Inverter Ducted Packaged Heat Pump - BTC 761701319 A (12.2022)
13.12 Temperature and Resistance Relationship Tables (for Sensors)
TEMP F TEMP C RESISTANCE k VOLTS DC TEMP F TEMP C RESISTANCE k VOLTS DC
-5 -20.6 107.732 4.65 90 32.2 7.225 2.36
0 -17.8 93.535 4.60 95 35.0 6.401 2.21
5 -15.0 79.521 4.54 100 37.8 5.683 2.07
10 -12.2 67.795 4.47 105 40.6 5.057 1.93
15 -9.4 57.948 4.39 110 43.3 4.509 1.79
20 -6.7 49.652 4.30 115 46.1 4.028 1.67
25 -3.9 42.645 4.21 120 48.9 3.606 1.55
30 -1.1 36.710 4.10 125 51.7 3.233 1.43
40 4.4 27.386 3.86 130 54.4 2.902 1.32
45 7.2 23.732 3.73 135 57.2 2.610 1.22
50 10.0 20.610 3.59 140 60.0 2.350 1.13
55 12.8 17.939 3.45 145 62.8 2.119 1.04
60 15.6 15.648 3.30 150 65.6 1.914 0.96
65 18.3 13.681 3.15 155 68.3 1.731 0.88
70 21.1 11.987 2.99 160 71.1 1.574 0.82
75 23.9 10.527 2.83 165 73.9 1.416 0.75
80 26.7 9.265 2.67 170 76.7 1.276 0.68
85 29.4 8.172 2.52
Table 36 for T2, T3, T4, Th, T3L