System Status Report by Domestic
Option Address Default
System status report by domestic (0 = no report,
1 = destination 1,
2 = destination 2,
3 = destination 3,
4 = destination 4,
5 = destination 1, 2, 3 and 4,
6 = destination 1 (2, 3, 4 for backup),
7 = destination 1, 3 (2, 4 for backup))
0139 0
Communication Operations Programming
Dual IP Settings
Option Address Default
Dual IP Settings (0 = 1 IP module, 1 = 2 IP modules) 0990 1
Notice!
Dual IP settings are valid only when used in the Conettix IP format. This programming option
is valid for B426 and ITS-DX4020-G modules. ITS-DX4020-G cannot be set as No. 2 IP module.
Module Address
ITS-DX4020-G module or B426- module 1 0134
B426 module 2 0250
Remote Access to Panel when Panel Is Armed
Option Address Default
Remote access to panel when panel is armed (0 =
disabled, 1 = enabled)
0929 1
Remote PC Setting
Option
Address Default
Remote PC IP address 0930 – 0941 15
Remote PC port number 0942 – 0946 15
AMAX panel DHCP update time (hours) 0947 15
Remote Programming (0 = disabled, 1 = enabled) 0970 1
8.1.3
AMAX panel Address Programming | en 115