Zone
No
Area Selection
Address
Default Zone Function
Selection
Address
Default Module
Selection
Address
Default
17 0710 - 0711 00 0822 1 0886 15
18 0712 - 0713 00 0823 1 0887 15
19 0714 - 0715 00 0824 1 0888 15
20 0716 - 0717 00 0825 1 0889 15
21 0718 - 0719 00 0826 1 0890 15
22 0720 - 0721 00 0827 1 0891 15
23 0722 - 0723 00 0828 1 0892 15
24 0724 - 0725 00 0829 1 0893 15
25 0726 - 0727 00 0830 1 0894 15
26 0728 - 0729 00 0831 1 0895 15
27 0730 - 0731 00 0832 1 0896 15
28 0732 - 0733 00 0833 1 0897 15
29 0734 - 0735 00 0834 1 0898 15
30 0736 - 0737 00 0835 1 0899 15
31 0738 - 0739 00 0836 1 0900 15
32 0740-0741 00 0837 1 0901 15
Value Range:
00 = zone not used,
1 - 16 = Area 1- 16
Value Range:0 –15. See
Section Zone Functions
0 = On-board zone
1 = Keypad Zone *
2 = DX2010 Zone **
3 = RF Device
15 = not used
* Zones 17 to 32 are dedicated to Keypad 1 to 32 (Zone 17 = Keypad 1, Zone 32 = Keypad 32)
** Zones 17 to 24 are dedicated to DX2010 address 103 ports 1 to 8, also see , page 124
Zones 25 to 32 are dedicated to DX2010 address 104 ports 1 to 8, also see , page 124
Notice!
When a zone is assigned to Keypad Zone (1) or RF Device (3), then the dedicated zone on
DX2010 is not available.
122 en | Programming
AMAX panel 4000 / AMAX panel 4000
EN
2013.07 | 03 | F.01U.267.112 Installation Guide Bosch Sicherheitsysteme GmbH