EasyManua.ls Logo

Bosch AMAX panel 4000 - System Fault or Tamper Analysis Mode in Text Keypad

Bosch AMAX panel 4000
176 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3
1
1
Onboard Output 1 Fault
2
Onboard Output 2 Fault
4
5
1
6
1
Communication Fault 1
2
Communication Fault 2
3
Communication Fault 3
4
Communication Fault 4
5
Phone Line Fault
7
Tamper
1
2
Keypad 1 – 16 Tamper
3
1 - 6
Zone Expansion Module 1 - 6 Tamper
4
Sensor Tamper DEOL
5
Zone type Tamper
6
1
Keypad Lock out
7
1
RF Receiver Tamper
8
1 - 8
RF Repeater Tamper
8
External Fault Zone 1-16
Keypad Failure
System Failure
Communication Failure
Onboard Output Failure
Keypad 1 – 16 Fault
Date Time not set
1 - 16
1 - 16
1 - 16
1 - 16
Output Failure
Keypad Tamper
System Tamper
1 - 16
External Failure
Zone Expansion Module Tamper
Zone Tamper DEOL
Zone type Tamper
Keypad Lock out
RF Receiver Tamper
RF Repeater Tamper
System Fault or Tamper Analysis Mode in Text Keypad
To enter fault or tamper analysis mode for determining a system fault or tamper condition:
a) Enter your Code + [2] [1] and press [#]. It beeps twice.
b) Scroll down with [ arrow] to display all trouble or fault conditions.
10.3.2
AMAX panel 4000 / AMAX panel 4000
EN
Keypad Usage and Operations | en 161
Bosch Sicherheitsysteme GmbH Installation Guide 2013.07 | 03 | F.01U.267.112

Table of Contents